Company: Link Technologies
Case No: L11703. Project: 10.10: LinkSOFT Version 10.1
Logged By: Rashna (Edge Business Solutions) on 10 Sep 2019 08:32AM
Priority: High
Product: Point of Sale
Group: Software Defect
Time Taken: 4.00 (Weight: 4.00)
Version: 10.155.0117
Assigned To: Sanjay (Link Technologies)
Circulation: Rashna, Sanjay
Resolve By: Saturday, 31 August 2019 12:00 AM [1899 days since logged date]
Status: Closed
Subject: Licence validation for "EFT", "FCI" and "REPL" fails when licence status is "Production"
Summary:    

Steps to Replicate

  1. Create a demo database and request a demo licence.
  2. System automatically issues 1 licence for  "EFT", "FCI" and "REPL". Used licence is 0
  3. Login into POS and BO this is allowed and users can use the system
  4. Mark the request as "Production" and set the licence to 0 users for  "EFT", "FCI" and "REPL". Issued licence = 0 and used = 0.
  5. Login into POS , login fails with message "Invalid Licence Code" for  "EFT", "FCI" and "REPL"

Setup 

  • Database - LINKSOFT-DEMO-10-RASHNA
  • Server - 10.0.0.14
Audit Notes:Edited by rashna on 10/09/19 08:32. Edited by sanjay on 30/08/19 13:22. Edited by sanjay on 30/08/19 13:20. 
30 Aug 201912:39PM Comment 1 by Rashna (Edge Business Solutions) Case 11703 added to project 10.150
30 Aug 201901:22PM Comment 2 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 30-08-2019 01:22 PM Time Taken: 3.00

Development work for this case has been completed.

The change will be available in version:10.150

1. The following changes were made(Include Database object names, Program classes and any other relevant information):

  1. Change licence check to validate only when usage > 0

2. Affected Areas:

  1. Login forms and User maintenance update

3. The issue was caused by:

  1. Licence check was validating Licence code even if the usage was zero

4. Notes
5. Next Step
: UAT


30 Aug 201902:14PM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 30-08-2019 02:14 PM Time Taken: 1.00 Notes: Edited by rashna on 30/08/19 14:27. 
QA Results
Tests carried out according to requirements specified on the case header

Test Results Summary

Table 1 - Summarised list of issues
NoTest DescriptionPass/Fail
1
Set the licence request as "Production"

Set the licence count for EFT, FCI, REPL to 0.
Issued Licence - 0
Used Licence - 0
Expiry Date - 31/01/2020 . This should allow users to login to thes system.


Set the licence count for EFT, FCI, REPL to 0.
Issued Licence - 0
Used Licence - 0
Expiry Date - 31/01/2000 . This should allow users to login to thes system.
Pass
2
Set the licence count for EFT, FCI 0.
Issued Licence - 0
Used Licence - 0
Expiry Date - 31/01/2000 .
Enable EFT and FCI for station LinkQA4. This should not be allowed. User should be able to login.
Pass
3
Set the licence count for EFT, FCI 0.
Issued Licence - 0
Used Licence - 0
Expiry Date - 31/01/2020 .
Enable EFT and FCI for station LinkQA4. This should not be allowed.User should be able to login
Pass
4
Set the licence count for EFT, FCI 0.
Issued Licence - 1
Used Licence - 0
Expiry Date - 31/01/2020 .
Enable EFT and FCI for station LinkQA4. This should be allowed.User should be able to login
Pass
5
Set the licence count for TNA, HEL, REC and FMS to 0.
Issued Licence - 0
Used Licence - 0
Expiry Date - 31/01/2020 This should allow users to login to thes system and reset password
Pass
6
Set the licence count for TNA, HEL, REC and FMS to 0.
Issued Licence - 0
Used Licence - 0
Expiry Date - 31/01/2000 This should allow users to login to thes system and reset password
Pass
7
Set the licence count for TNA, HEL, REC and FMS to 0.
Issued Licence - 0
Used Licence - 0
Expiry Date - 31/01/2000 This should allow users to login to thes system and reset password
Enable TNA, HEL, REC and FMS access for user admin - This should mark the licence as invalid
Pass
8
Set the licence count for HRM as below.
Issued Licence - 1
Employee Count - 50
Active employees are 52. This should disable system use with invalid employee count
Pass

Environment Details

  1. OS version: Windows Server 2012
  2. Application version: 10.150.0
  3. Setup: Demo
  4. Server : 10.0.0.14
  5. Database: LINKSOFT-DEMO-10-CASE11073

Next Step

  1. Closure

    07 Sep 201902:20PM Comment 4 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 07-09-2019 02:20 PM
    Thanks Rashna

    10 Sep 201908:32AM Comment 5 by Rashna (Edge Business Solutions) Case 11703 removed from project 10.150
    10 Sep 201908:32AM Comment 6 by Sanjay (Link Technologies) Case 11703 added to project 10.150
    If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L11703 in the subject line of all emails regarding this issue.