Company: Link Technologies
Case No: L10531. Project: 11.40: LinkSOFT Version 11.4
Logged By: Rashna (Edge Business Solutions) on 02 Aug 2019 10:41AM
Priority: Medium
Product: Point of Sale
Group: Enhancement
Time Taken: 5.50 (Weight: 5.50)
Version: 11.3.0902
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Friday, 09 August 2019 12:00 AM [1938 days since logged date]
Status: Closed
Subject: Add wrapping to the kit details in the "Inventory Kit Listing" report.
Summary:    

Apply the report framework and add wrapping to the "Inventory Kit Listing" report.

Figure 1: Report



Audit Notes:
02 Aug 201910:41AM Comment 1 by Rashna (Edge Business Solutions) Case 10531 added to project 11.0
05 Aug 201910:07AM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 05-08-2019 10:07 AM Time Taken: 3.50

Development work for this case has been completed.

The change will be available in version: 11.0.0805

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. Removed report "Inventory Kit Listing"
  2. This report can be generated from "Inventory Listing Report" using Product type filter = Kit

2. The issue was caused by:

  1. Improvement

3. Next Step:

  1. UAT

4. Notes:


12 Aug 201910:52AM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 12-08-2019 10:52 AM Time Taken: 2.00
QA Results
Tests carried out according to requirements specified on the case header

Test Results Summary

Table 1 - Summarised list of issues
NoTest DescriptionPass/Fail
1Verify that the "Inventory Kit Listing" has been removed from the systemPass
2Verify that the kit component description (Baked Small Kids Combo Fries (Lewis Shredders & Green Tomates) is fully printed in the "Inventory Listing Report"  Pass

Environment Details

  1. OS version: Windows Server 2012
  2. Application version: 11.0.805
  3. Setup: Demo
  4. Server : 10.0.0.14
  5. Database: LINKSOFT-DEMO-11-RASHNA

Next Step:

  • Closure

    09 Oct 201908:17AM Comment 4 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - Cleared queue due to large number of calls
    If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L10531 in the subject line of all emails regarding this issue.

    Document size: 33.7 KB
    For call complaints, please contact the Managing Director of the company using this form