Company: Link Technologies
Case No: L10465. Project: 11.40: LinkSOFT Version 11.4
Logged By: Rashna (Edge Business Solutions) on 10 Jun 2019 02:49PM
Priority: High
Product: Payroll & HR
Group: Software Defect
Time Taken: 10.00 (Weight: 10.00)
Version: 11.3.0902
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Tuesday, 11 June 2019 12:00 AM [1991 days since logged date]
Status: Closed
Subject: Unable to "Create" or "Edit" a leave transaction in web.
Summary:    

Steps to Replicate

  1. Navigate to "Leave Management - Leave Transactions"
  2. Search for employee E022.
  3. Add a new transaction. Save fails. Refer to Figure 1.

Figure 1: Error


Audit Notes:Edited by sanjay on 11/09/19 15:48. 
10 Jun 201902:49PM Comment 1 by Rashna (Edge Business Solutions) Case 10465 added to project 11.0
11 Jun 201902:21PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 11-06-2019 02:21 PM Time Taken: 2.50

Development work for this case has been completed.

The change will be available in version: 11.0.20190611

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. Corrected interface to the save/update procedure

2. The issue was caused by:

  1. Incorrect procedure interface

3. Next Step:

  1. UAT

25 Jun 201902:30PM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Alvis (Link Technologies) Followup Date: 25-06-2019 02:30 PM Time Taken: 2.50
QA Results
Tests carried out according to requirements specified on the case header

Test Results Summary

Table 1 - Summarised list of issues
NoTest DescriptionPass/Fail
1 Users should able to "Create" and "Edit" a leave transaction.Pass
2

Following should be required 

  1. Leave Code
  2. Status
  3. Approved By
Pass
3The "Transaction ID" should be depicted from the configuration "Next Leave Transaction Number" 

Fail

Users can enter any text in the "Transaction ID"field and this is saved.

4Validate that the leave "To Date" is not less than the "From Date"Pass
5Hours Taken can not be blank or 0

Fail

Users can save "Hours Taken" as blank.

In version 10, we prompted message that "Taken must be greater than 0"

6Users should be able to "Void" a transaction Pass

Environment Details

  1. OS version: Windows Server 2012
  2. Application version: 11.0.0624
  3. Setup: Demo
  4. Server : 10.0.0.14
  5. Database: LINKSOFT-DEMO-11-RASHNA

Next Step: Correction



    27 Jun 201910:37AM Comment 4 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 27-06-2019 10:37 AM Time Taken: 2.50

    Development work for this case has been completed.

    The change will be available in version: 11.0.0626

    1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

    1. The transaction ID is made read-only on add and edit
    2. Added validation for Hours Taken to be greater than 0.

    2. The issue was caused by:

    1. Improvement

    3. Next Step:

    1. UAT

    4. Notes:


    27 Jun 201910:51AM Comment 5 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 27-06-2019 10:51 AM Time Taken: 2.50
    QA Results
    Tests carried out according to requirements specified on the case header

    Test Results Summary

    Table 1 - Summarised list of issues
    NoTest DescriptionPass/Fail
    1Validate that the "Transaction ID" field is read only on Ädd" and "Edit"Pass
    2"Hours Taken" should be greater than 0. Users should be able to enter "Hours Taken" as "Null", "0" or negativesPass

    Environment Details

    1. OS version: Windows Server 2012
    2. Application version: 11.0.0624 BETA
    3. Setup: Demo
    4. Server : 10.0.0.14
    5. Database: LINKSOFT-DEMO-11-RASHNA

    Next Step: Pass


      09 Oct 201908:17AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - Cleared queue due to large number of calls
      If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L10465 in the subject line of all emails regarding this issue.

      Document size: 60.9 KB
      For call complaints, please contact the Managing Director of the company using this form