Company: Link Technologies
Case No: L12029. Project: 11.40: LinkSOFT Version 11.4
Logged By: Sanjay (Link Technologies) on 03 Sep 2020 04:28PM
Priority: High
Product: Point of Sale
Group: Software Defect
Time Taken: 6.00 (Weight: 6.00)
Version: 11.4.0903
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Sanjay
Resolve By: Thursday, 03 September 2020 11:59 PM [1540 days since logged date]
Status: Closed
Subject: Touch Screen number pad pops up even if the user does not have access to Change Price [Created from case L12028]
Summary:    

Development work for this case has been completed.

The change will be available in version:12.0.0903

1. The following changes were made(Include Database object names, Program classes and any other relevant information):

  1. Changed the POPUP Keyboard to load only if the control is editable

2. Affected Areas:

  1. Touch screen forms

3. The issue was caused by:

  1. Design issue

4. Notes
5. Next Step
: UAT

----------------------

Development Reference:

Audit Notes:Edited by sanjay on 04/09/20 15:08. 
03 Sep 202004:28PM Comment 1 by Sanjay (Link Technologies) Created from case L12028
03 Sep 202004:29PM Comment 2 by Sanjay (Link Technologies)

Case L12029 added to project build LinkSOFT 11.4.0903.

Development completed. Please proceed with UAT.

04 Sep 202001:55PM Comment 3 by Alvis (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 04-09-2020 07:15 PM Time Taken: 2.00
QA Results
Tests carried out according to requirements specified on the case header

Test Results Summary

Table 1 - Summarised list of issues
NoTest DescriptionPass/Fail
1Login to POS with Cashier (no access to change price). Try changing price with/without touch screen enabled.Pass. The user was not able to change the price without authorization from the manager.
2Login to POS with admin (has access to change price). Try changing price with/without touch screen enabled.Pass

Environment Details

  1. OS version: Windows Server 2012
  2. Application version: 11.0.0903GA
  3. Setup: Demo
  4. Server : 10.0.0.11
  5. Database: LINKSOFT

Next Step

  1. Release GA

    04 Sep 202003:08PM Comment 4 by Sanjay (Link Technologies) ETC was changed from 03/09/2020 to 03/09/2020