Company: Link Technologies
Case No: L11740. Project: 11.40: LinkSOFT Version 11.4
Logged By: Alvis (Link Technologies) on 17 Oct 2019 01:09PM
Priority: High
Product: Point of Sale
Group: Enhancement
Time Taken: 3.00 (Weight: 3.00)
Version: 11.4.0903
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Monday, 23 September 2019 12:00 AM [1862 days since logged date]
Status: Closed
Subject: JIWA UPC code is not integrated to LinkSOFT
Summary:    Clients store the barcode of an item in JIWA ~> UPC code field. This field is not integrated into the POS product master.
Audit Notes:Edited by alvis on 17/10/19 13:09. Edited by alvis on 23/09/19 14:10. 
23 Sep 201912:05PM Comment 1 by Alvis (Link Technologies) Case 11740 added to project 11.004.BETA
23 Sep 201902:10PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 23-09-2019 02:10 PM Time Taken: 2.00

Development work for this case has been completed.

The change will be available in version:11.004

1. The following changes were made(Include Database object names, Program classes and any other relevant information):

  1. Changed the JIWA to POS integration to update inventory UPC code.

2. Affected Areas:

  1. JIWA to POS integration for using JIWA inventory

3. The issue was caused by:

  1. Improvement

4. Notes
5. Next Step
: UAT


27 Sep 201908:23AM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 27-09-2019 08:23 AM Time Taken: 1.00
QA Results
Tests carried out according to requirements specified on the case header

Test Results Summary

Table 1 - Summarised list of issues
NoTest DescriptionPass/Fail
1Create a Product as R1001 in JIWA. Set the UPC code as 8890348. The UPC code on menu 519 should be updated to 8890348. Pass
2Update the UPC code to "DP-8890348"  for product R1001 in JIWA. The UPC code on menu 519 should be updated to DP-8890348
Pass

Environment Details

  1. OS version: Windows Server 2012
  2. Application version: 11.4.0926
  3. Setup: Demo
  4. Server : 10.0.0.14
  5. Database: LINKSOFT-DEMO-11-RASHNA
  6. JIWA DB - JIWA-11, Version 7.2.1

Next Step

  1. Closure

    17 Oct 201901:09PM Comment 4 by Alvis (Link Technologies) Case 11740 removed from project 11.004.BETA
    17 Oct 201901:09PM Comment 5 by Alvis (Link Technologies) Case 11740 added to project 11.004.BETA
    If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L11740 in the subject line of all emails regarding this issue.

    Document size: 4.9 KB