Company: Link Technologies
Case No: L12686
Logged By: Aarti Pooja Gayaneshwar (Link Business Solutions) on 11 Mar 2022 02:25PM
Priority: High
Product: Point of Sale
Group: Software Defect
Time Taken: 10.00 (Weight: 10.00)
Version: Upgrade to V13
Assigned To: Sanjay (Link Technologies)
Circulation: Aarti Pooja Gayaneshwar, Sanjay
Resolve By: Saturday, 12 March 2022 12:00 AM [986 days since logged date]
Status: Closed
Subject: Unable to Upgrade Bargain Box Database - BBOX-LINKSOFT-DEEMALL
Summary:    

Hi Sanjay

BBox database was being upgraded from V949 to V13 and we found the below error:

Violation of PRIMARY KEY constraint 'PK_LT_FMS_PUR_RequestDetail'. Cannot insert duplicate key in object 'dbo.LT_FMS_PUR_RequestDetail'. The duplicate key value is (161144b0-523e-f9d9-2877-1f26f601e74b).
The statement has been terminated.

Database restored on QA8
Database Name: BBOX-LINKSOFT-DEEMALL

Audit Notes:Edited by sanjay on 18/03/22 08:06. Edited by aarti on 11/03/22 14:25. 
11 Mar 202203:53PM Comment 1 by Sanjay (Link Technologies) Assigned To: Aarti Pooja Gayaneshwar (Link Business Solutions) Followup Date: 11-03-2022 09:53 PM Time Taken: 1.00
Hi Aarti, These are all data issues in the upgrade. Let's connect next week Tuesday 2 PM AEST and I can help resolve these

16 Mar 202208:37AM Comment 2 by Sanjay (Link Technologies) Assigned To: Aarti Pooja Gayaneshwar (Link Business Solutions) Followup Date: 16-03-2022 02:18 PM Time Taken: 4.00

The issue here is that there are Purchase Requests that have the same Part Number repeating multiple times in the Purchase Request Details. We have resolved the script and placed a patch for this on FTP. Patch Number: LinkSOFT_13.30.0316.zip is located at this link.

Aarti please confirm the issue has been resolved and assign this case to me for closure. thanks.


16 Mar 202210:33AM Comment 3 by Aarti Pooja Gayaneshwar (Link Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 16-03-2022 04:28 PM Time Taken: 1.00
The following tests were performed:

Table 1 - Test Results
NoTest CaseExpected ResultPass/FailComments
1Restored Database
Pass


2Applied Script
Pass


3Upgrade Database
Fail


4Upgrade Error
Execution Timeout Expired. The timeout period elapsed prior to completion of the operation or the server is not responding.

EXEC LT_SAA_DataMigration_PostUpgrade

Script File: 99998


5



Environment Details

  1. OS version: Win10
  2. Application version: 13.30
  3. Setup on:
    1. Server: LinkQA8
    2. Database: BBOX-LINKSOFT-DEEMALL
    3. LinkSOFT URL:
  4. Login Details: Standard username and password for user "admin"

Next Step


16 Mar 202210:52AM Comment 4 by Sanjay (Link Technologies) Assigned To: Aarti Pooja Gayaneshwar (Link Business Solutions) Followup Date: 16-03-2022 04:46 PM Time Taken: 2.00

Hi Aarti, the data conversion time taken will depend on the power of the server and also the connection timeout n the database utility.

The default is 3600s = 1 hour. You should increase this for larger databases.

The configuration file is located in the installed folder, file name: C:\Program Files (x86)\Link Technologies\Link Technologies - DatabaseUtility.exe.config

Section to change: <add key="DataConnectionCommandTimeout" value="3600"/>. If you want to use 2 hours, use 7200 instead of 3600


17 Mar 202201:51PM Comment 5 by Aarti Pooja Gayaneshwar (Link Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 17-03-2022 07:50 PM Time Taken: 2.00
The following tests were performed:

Table 1 - Test Results
NoTest CaseExpected ResultPass/FailComments
1Restored Database
Pass


2Applied Script
Pass


3Upgrade Database
Pass

2 hours and 6 mins
4


5



Environment Details

  1. OS version: Win10
  2. Application version: 13.30
  3. Setup on:
    1. Server: LinkQA8
    2. Database: BBOX-LINKSOFT-DEEMALL
    3. LinkSOFT URL:
  4. Login Details: Standard username and password for user "admin"

Next Step: For closure


18 Mar 202208:06AM Comment 6 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 18-03-2022 02:05 PM
Thanks Aarti

If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L12686 in the subject line of all emails regarding this issue.

Document size: 13.2 KB
For call complaints, please contact the Managing Director of the company using this form