Company: Link Technologies
Case No: L12950. Project: 15.00: LinkSOFT Version 15.00
Logged By: Sanjay (Link Technologies) on 21 Sep 2023 09:01AM
Priority: High
Product: Framework
Group: Enhancement
Time Taken: 9.00 (Weight: 10.00)
Assigned To: Development
Circulation: Development, Sanjay, Vineshwar Prasad
Resolve By: Wednesday, 27 September 2023 08:23 PM [427 days since logged date]
Status: Closed
Subject: Link Licence Portal compliance with TLS 1.2 and 1.3
Summary:    Add Link Licence Portal compliance with TLS 1.2 and 1.3
Audit Notes:
21 Sep 202304:28PM Comment 1 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 27-09-2023 08:23 PM Time Taken: 6.00 Notes: ETC extended from: 21/09/2023 to 27/09/2023
PART A - Development work for this case has been completed.

1. The change will be available in version: 15.00

2. The following changes were made(Include Database object names, Program classes, and any other relevant information):

  1. Found that the LinkSOFT Licence Portal was not upgraded to TLS 1.2/1.3. Added code in LinkSOFT Licence Request to handle TLS1.2 and above

3. Affected Areas:

  1. Licence Request

4. The issue was caused by:

  1. Security Improvement

5. Other Relevant Notes:

  1. Refer to figure 1 and 2 for TLS Confirmation

6. Next Step (Review and System Test (Developer) -> UAT (Quality) -> Documentation): UAT


Figure 1 - LinkSOFT Version 14.0 uses TLSV1 for Licence Request


Figure 2 - LinkSOFT Version 14.1 and Above uses TLSV2 or V3 for Licence Request


22 Sep 202303:38PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 27-09-2023 07:37 PM Time Taken: 3.00
The following tests were performed:

Table 1 - Test Results
NoTest CaseExpected ResultPass/FailComments
1Request Licence and measure TLS version
TLS  1.2 should be used
Pass

Environment Details

  1. OS version: Win11
  2. Application version: 15.00
  3. Setup on:
    1. Server: LinkQA4
    2. Database: LinkSOFT
    3. LinkSOFT URL: HTTP://LinkQA4/LinkSOFT
  4. Login Details: Standard username and password for user "admin"

Next Step: Closure