Company: Link Technologies
Case No: L12778. Project: 14.10: LinkSOFT version 14.10 - October 2022
Logged By: Sanjay (Link Technologies) on 23 Aug 2022 02:24PM
Priority: Low
Product: Framework
Group: Enhancement
Time Taken: 9.00 (Weight: 10.00)
Assigned To: Development
Circulation: Development, Sanjay
Resolve By: Friday, 30 September 2022 12:00 AM [821 days since logged date]
Status: Closed
Subject: User Password Reset should BYPASS the "System.Operating.Mode"
Summary:    User Password Reset should BYPASS the "System.Operating.Mode" so password resets cn be sent to the actual user for Test Environments
Audit Notes:Edited by sanjay on 26/09/22 13:31. Edited by sanjay on 06/09/22 14:27. 
25 Aug 202203:50PM Comment 1 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 02-09-2022 03:49 PM Time Taken: 6.00
PART A - Development work for this case has been completed.

1. The change will be available in version:14.10

2. The following changes were made(Include Database object names, Program classes, and any other relevant information):

  1. When user password is reset, we bypass "System.Operating.Mode" as the emails should go to the appropriate users

3. Affected Areas:

  1. User Maintenace

4. The issue was caused by:

  1. Change to design based on new requirements

5. Other Relevant Notes
6. Next Step
(Review and System Test (Developer) -> UAT (Quality) -> Documentation): UAT


PART B -
Development Reference (Place descriptor for objects changed)
: Email Password changed to bypass Operating.Mode.


26 Sep 202211:48AM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 30-09-2022 11:47 AM Time Taken: 3.00
The following tests were performed:

Table 1 - Test Results
NoTest CaseExpected ResultPass/FailComments
1Set the system.Operating.Mode to TEST. Reset a users password
Reset password email should bypass the "TEST MODE" password and go directly to the user
Pass

2Recover Password in TEST Mode
Recover password email should bypass the "TEST MODE" password and go directly to the user
Pass

Environment Details

  1. OS version: Win11
  2. Application version: 14.10
  3. Setup on:
    1. Server: LinkQA4
    2. Database: LinkSOFT
    3. LinkSOFT URL: HTTP://LinkQA4/LinkSOFT
  4. Login Details: Standard username and password for user "admin"

Next Step: Closure