Subject: | POS Login Screen does not retain the saved Station layout |
Summary: | POS Login Screen - Station changes to the 1st option in the list. The station lookup should retain its value when it gets focus. If the saved Station Layout is invalid, ask the user to choose a station. Test cases: - Change the Default Station in the "App.config" to an invalid value.
- Log into POS without changing the Station Layout. There should be a prompt saying "Station Layout is invalid, Choose a valid Station Layout".
- Open the login Screen to POS. Choose the 3rd Station layout. Log into POS. The default Station layout saved should be the third one on the list.
- Log out of POS
- Open the POS Login Screen and click on the "Station Dropdown". The selected value should be the third item in the Station List
|
Audit Notes: | Edited by alvis on 05/03/21 14:00. Edited by alvis on 03/03/21 13:08. Edited by sanjay on 03/03/21 09:04. Edited by sanjay on 03/03/21 08:08. Edited by sanjay on 26/02/21 11:41. Edited by alvis on 26/02/21 11:31. Edited by alvis on 26/02/21 11:31. Edited by alvis on 26/02/21 11:30. Edited by alvis on 26/02/21 11:30. Edited by alvis on 25/02/21 10:53. Edited by alvis on 25/02/21 10:37. Edited by alvis on 25/02/21 10:37. |
25 Feb 2021 | 10:18AM Comment 1 by Sanjay (Link Technologies) Case L12176 added to project 12.4 |
25 Feb 2021 | 10:53AM Comment 2 by Alvis (Link Technologies) ETC was changed from 01/03/2021 to 01/03/2021 |
26 Feb 2021 | 11:41AM Comment 3 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 03-03-2021 01:41 PM Time Taken: 1.00 |
| Added test cases to header |
|
03 Mar 2021 | 08:08AM Comment 4 by Sanjay (Link Technologies) Case L12176 added to project 12.3 |
03 Mar 2021 | 09:03AM Comment 5 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 05-03-2021 10:58 AM Time Taken: 4.00 |
| PART A - Development work for this case has been completed. 1. The change will be available in version: 12.32.0303 2. The following changes were made(Include Database object names, Program classes, and any other relevant information): - When the station layout is initially loaded, the value is displayed from the APP.CONFIG file, pre-configured value.
- When the Station layout is changed, we match the predefined (Or last valid Login) value to the list of available stations. If one exists, we select this, otherwise, we select the first one.
3. Affected Areas: - POS Login form - Select a station
4. The issue was caused by: - Default not applied in the original design
5. Notes: 6. Next Step (Review and System Test (Developer) -> UAT (Quality) -> Documentation): System Test |
|
03 Mar 2021 | 09:04AM Comment 6 by Sanjay (Link Technologies) ETC was changed from 01/03/2021 to 12/03/2021 |
15 Mar 2021 | 09:33AM Comment 7 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 17-03-2021 11:18 AM Time Taken: 0.50 |
| QA Results Tests carried out according to requirements specified on the case header Test Results Summary Table 1 - Summarised list of issues No | Test Description | Pass/Fail | 1 | When the station layout is initially loaded, the value is displayed from the APP.CONFIG file, pre-configured value. - Default Station in the config file is "ST1- General".
- Load POS, station selected should be "General".
- Login and Verify
| Pass | 2 | When the Station layout is changed, we match the predefined (Or last valid Login) value to the list of available stations. If one exists, we select this, otherwise, we select the first one. - On the POS Login screen, change the station to "Electronics".
- Login into POS, Fast keys should show electrical items.
- Log out and Load POS, the station should be defaulted to "Electronics" - Last Valid Login.
- Login and void the station "Electronics".
- Load POS Login page, this should be updated with the station first on the list - Bar
| Pass |
Environment Details - OS version: Windows Server 2012
- Application version: 12.32.0312BETA
- Setup: Demo
- Server : 10.0.0.14
- Database: LINKSOFT-DEMO-123
Next Step: - For Closure
|
|
15 Mar 2021 | 04:07PM Comment 8 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 17-03-2021 06:06 PM |
| Thanks Rashna |
|