Company: Link Technologies
Case No: L12176. Project: 12.30: LinkSOFT Version 12.30
Logged By: Sanjay (Link Technologies) on behalf of Alvis (Link Technologies) on 24 Feb 2021 01:23PM
Priority: Low
Product: Point of Sale
Group: Software Defect
Time Taken: 5.50 (Weight: 5.50)
Version: 12.32
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Friday, 12 March 2021 11:59 PM [1366 days since logged date]
Status: Closed
Subject: POS Login Screen does not retain the saved Station layout
Summary:    

POS Login Screen - Station changes to the 1st option in the list. The station lookup should retain its value when it gets focus.

If the saved Station Layout is invalid, ask the user to choose a station.

Test cases:

  1. Change the Default Station in the "App.config" to an invalid value.
    1. Log into POS without changing the Station Layout. There should be a prompt saying "Station Layout is invalid, Choose a valid Station Layout".
  2. Open the login Screen to POS. Choose the 3rd Station layout. Log into POS. The default Station layout saved should be the third one on the list.
    1. Log out of POS
    2. Open the POS Login Screen and click on the "Station Dropdown". The selected value should be the third item in the Station List
Audit Notes:Edited by alvis on 05/03/21 14:00. Edited by alvis on 03/03/21 13:08. Edited by sanjay on 03/03/21 09:04. Edited by sanjay on 03/03/21 08:08. Edited by sanjay on 26/02/21 11:41. Edited by alvis on 26/02/21 11:31. Edited by alvis on 26/02/21 11:31. Edited by alvis on 26/02/21 11:30. Edited by alvis on 26/02/21 11:30. Edited by alvis on 25/02/21 10:53. Edited by alvis on 25/02/21 10:37. Edited by alvis on 25/02/21 10:37. 
25 Feb 202110:18AM Comment 1 by Sanjay (Link Technologies) Case L12176 added to project 12.4
25 Feb 202110:53AM Comment 2 by Alvis (Link Technologies) ETC was changed from 01/03/2021 to 01/03/2021
26 Feb 202111:41AM Comment 3 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 03-03-2021 01:41 PM Time Taken: 1.00
Added test cases to header

03 Mar 202108:08AM Comment 4 by Sanjay (Link Technologies) Case L12176 added to project 12.3
03 Mar 202109:03AM Comment 5 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 05-03-2021 10:58 AM Time Taken: 4.00

PART A - Development work for this case has been completed.

1. The change will be available in version: 12.32.0303

2. The following changes were made(Include Database object names, Program classes, and any other relevant information):

  1. When the station layout is initially loaded, the value is displayed from the APP.CONFIG file, pre-configured value. 
  2. When the Station layout is changed, we match the predefined (Or last valid Login) value to the list of available stations. If one exists, we select this, otherwise, we select the first one.

3. Affected Areas:

  1. POS Login form - Select a station

4. The issue was caused by:

  1. Default not applied in the original design

5. Notes
6. Next Step
(Review and System Test (Developer) -> UAT (Quality) -> Documentation): System Test


03 Mar 202109:04AM Comment 6 by Sanjay (Link Technologies) ETC was changed from 01/03/2021 to 12/03/2021
15 Mar 202109:33AM Comment 7 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 17-03-2021 11:18 AM Time Taken: 0.50
QA Results
Tests carried out according to requirements specified on the case header

Test Results Summary

Table 1 - Summarised list of issues
NoTest DescriptionPass/Fail
1

When the station layout is initially loaded, the value is displayed from the APP.CONFIG file, pre-configured value.

  1. Default Station in the config file is "ST1- General".
  2. Load POS, station selected should be "General".
  3. Login and Verify 
Pass
2
When the Station layout is changed, we match the predefined (Or last valid Login) value to the list of available stations. If one exists, we select this, otherwise, we select the first one.
  1. On the POS Login screen, change the station to "Electronics".
  2. Login into POS, Fast keys should show electrical items.
  3. Log out and Load POS, the station should be defaulted to "Electronics" - Last Valid Login.
  4. Login and void the station "Electronics".
  5. Load POS Login page, this should be updated with the station first on the list - Bar
Pass

Environment Details

  1. OS version: Windows Server 2012
  2. Application version: 12.32.0312BETA
  3. Setup: Demo
  4. Server : 10.0.0.14
  5. Database: LINKSOFT-DEMO-123

Next Step

  1. For Closure

    15 Mar 202104:07PM Comment 8 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 17-03-2021 06:06 PM
    Thanks Rashna

    If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L12176 in the subject line of all emails regarding this issue.

    Document size: 8.2 KB
    For call complaints, please contact the Managing Director of the company using this form