Company: Link Technologies
Case No: L13098. Project: 15.60: LinkSOFT Version 15.60
Logged By: Sanjay (Link Technologies) on 28 Jan 2025 12:44PM
Priority: Low
Product: Payroll & HR
Group: Software Defect
Time Taken: 11.00 (Weight: 12.00)
Assigned To: Sanjay (Link Technologies)
Circulation: Development, Sanjay, Vineshwar Prasad
Resolve By: Friday, 28 February 2025 12:44 PM [4 days since logged date]
Status: Closed
Subject: System does not allow "Leave Adjustment" amount to be negative
Summary:    System does not allow "Leave Adjustment" amount to be negative. We are able to do negative adjustments from the screen.
Audit Notes:Edited by sanjay on 29/01/25 12:14. Edited by sanjay on 29/01/25 12:12. 
29 Jan 202512:13PM Comment 1 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 31-01-2025 02:12 PM Time Taken: 6.00
PART A - Development work for this case has been completed.

1. The change will be available in version: 15.60

2. The following changes were made (Include Database object names, Program classes, and any other relevant information):

  1. Removed validation to prevent "Negative" adjustments

3. Affected Areas:

  1. Import Adjustments

4. The issue was caused by:

  1. System Issue

5. Other Relevant Notes
6. Next Step
(Review and System Test (Developer) -> UAT (Quality) -> Documentation): UAT


29 Jan 202512:14PM Comment 2 by Sanjay (Link Technologies) ETC was changed from 28/01/2025 to 28/02/2025
29 Jan 202503:33PM Comment 3 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 31-01-2025 05:32 PM Time Taken: 4.00
The following tests were performed:

Test Setup Instructions:
  1. Standard Demo Environment
Table 1 - Test Results
NoTest CaseExpected ResultPass/FailComments
1Perform a "Leave Adjustment" which has a "negative" amount
System should allow and perform standard validations
Pass

Environment Details

  1. OS version: Win11
  2. Application version: 15.51.250129
  3. Setup on:
    1. Server: LinkQA5
    2. Database: LinkSOFT
    3. LinkSOFT URL: HTTP://LinkQA5/LinkSOFT
  4. Login Details: Standard username and password for user "admin"

Next Step: Closure


30 Jan 202511:10AM Comment 4 by Vineshwar Prasad (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 30-01-2025 12:25 PM Time Taken: 1.00
The following tests were performed:

Test Setup Instructions:
  1. Created Employee L002
  2. Allocated Leace Code AAL10 - BFW 55
Table 1 - Test Results
NoTest CaseExpected ResultPass/FailComments
1Perform a "Leave Adjustment" which has a "negative" amount using the Import template
The system should Validate and Post the file
Pass

2



Environment Details

  1. OS version: Win11
  2. Application version: 15.51.250129.GA
  3. Setup on:
    1. Server: LINKAD
    2. Database: DEMO-LinkSOFT-EDGE
    3. LinkSOFT URL: https://linktechnologies.com.au/DEMO-LinkSOFT-EDGE